REGISTRATION CAMA 2020 Guide

How Do You Register an Aviation Fuel Storage Tank Ultrasonic Thickness Testing Contractor with CAC and NCAA?

CACTalks Verified
Oct 20, 2026 • 4 min read
How Do You Register an Aviation Fuel Storage Tank Ultrasonic Thickness Testing Contractor with CAC and NCAA?
How Do You Register an Aviation Fuel Storage Tank Ultrasonic Thickness Testing Contractor with CAC and NCAA?
Quick Overview

Key Takeaways & Regulatory Highlights

  • NDT Personnel Qualifications: Testing technicians and inspection supervisors must hold valid certifications under the American Society for Nondestructive Testing (ASNT Level II or Level III)...
  • API 653 Inspector Certification: For above-ground atmospheric storage tanks holding aviation fuel, having an American Petroleum Institute (API 653) certified tank inspector on the engineering roster...
  • Apparatus Calibration Certificates: All digital ultrasonic thickness gauges, phased array transducers, and calibration step wedges must possess valid, traceable calibration certificates issued by accredited metrology...
  • Application to DAAS: Submit a formal application to the NCAA Directorate of Aerodrome and Airspace Standards requesting approval to provide aviation fuel storage facility inspection...

You register an aviation fuel storage tank ultrasonic thickness testing contractor in Nigeria by incorporating a private limited liability company with the Corporate Affairs Commission, securing professional engineering accreditations, and obtaining formal certification from the Nigeria Civil Aviation Authority and the Nigerian Midstream and Downstream Petroleum Regulatory Authority. Ultrasonic thickness testing is a critical non-destructive testing method that determines wall thinning, internal corrosion, and structural integrity in aviation turbine kerosene bulk storage facilities located at airports and supply terminals.

Aviation fuel infrastructure demands the highest safety and quality standards to eliminate fuel contamination and environmental leakage. Because non-destructive testing directly impacts aviation flight safety, the NCAA and NMDPRA prohibit oil service contractors from executing integrity inspections on Jet A-1 storage tanks without formal regulatory licensing and verified technical qualifications.

Step 1: Corporate Affairs Commission Incorporation Under CAMA 2020

The contractor must be registered as a corporate entity on the CAC Company Registration Portal, as sole proprietorships or unregistered business names are statutorily ineligible for aviation technical licenses.

  1. Reserve an appropriate corporate name that reflects technical inspection and non-destructive testing services.
  2. Draft the Memorandum and Articles of Association to explicitly cover specialized non-destructive testing, ultrasonic flaw detection, aviation fuel depot integrity inspections, tank calibration, and asset integrity management.
  3. Issue an authorized share capital that satisfies technical contracting standards. A minimum share capital of 10,000,000 to 25,000,000 Naira is recommended to satisfy pre-qualification criteria set by major aviation fuel marketers and airport terminal operators.
  4. Submit director and shareholder details, ensuring at least one founding director is a certified engineering professional registered with the Council for the Regulation of Engineering in Nigeria.

Step 2: Technical Personnel Certification and Equipment Calibration

Prior to submitting regulatory applications to the NCAA, the contractor must establish its technical competence through certified personnel and calibrated diagnostic equipment.

  • NDT Personnel Qualifications: Testing technicians and inspection supervisors must hold valid certifications under the American Society for Nondestructive Testing (ASNT Level II or Level III) or ISO 9712 / PCN standards in Ultrasonic Testing (UT).
  • API 653 Inspector Certification: For above-ground atmospheric storage tanks holding aviation fuel, having an American Petroleum Institute (API 653) certified tank inspector on the engineering roster is standard industry practice.
  • Apparatus Calibration Certificates: All digital ultrasonic thickness gauges, phased array transducers, and calibration step wedges must possess valid, traceable calibration certificates issued by accredited metrology laboratories.

Step 3: Securing NMDPRA Oil and Gas Industry Service Permits

Because aviation fuel storage tanks fall under midstream petroleum infrastructure, contractors must obtain operational permits from the Nigerian Midstream and Downstream Petroleum Regulatory Authority.

  1. Register on the NMDPRA contractor portal under the Major or Specialized Category for Quality Control, Inspection, and Non-Destructive Testing Services.
  2. Upload CAC corporate documents, Tax Clearance Certificates, evidence of Department of Petroleum Resources legacy compliance, and medical fitness certificates for site inspection personnel.
  3. Pay the prescribed statutory application and processing fees to secure the official NMDPRA Permit to Operate as a specialized inspection contractor.

Step 4: NCAA Certification and Technical Service Provider Approval

The primary aviation statutory authorization is granted by the Nigeria Civil Aviation Authority under the Civil Aviation Act 2022 and Nigeria Civil Aviation Regulations.

  • Application to DAAS: Submit a formal application to the NCAA Directorate of Aerodrome and Airspace Standards requesting approval to provide aviation fuel storage facility inspection and testing services.
  • Technical Documentation Submission: Provide comprehensive Standard Operating Procedures (SOP), an Enterprise Safety Management System (SMS) manual, quality assurance protocols, and emergency contingency procedures.
  • NCAA Technical Audit: NCAA aerodrome safety inspectors will conduct an on-site audit of your operational base, reviewing calibration logs, technician credential files, testing procedures, and field safety gear.
  • Issuance of NCAA Authorization: Upon satisfactory completion of the technical audit, the NCAA issues a formal Technical Service Provider Approval letter authorizing the company to perform ultrasonic testing on airport fuel hydrants and depot storage tanks.

Step 5: Commercial Deployment and Industry Compliance

Once regulatory approvals are secured, the contractor can enter commercial inspection agreements with aviation fuel into-plane service providers, international airlines, and the Federal Airports Authority of Nigeria.

Every completed ultrasonic thickness inspection must generate a formal technical integrity report documenting corrosion rates, remaining tank wall thickness, safe operating pressures, and next scheduled inspection intervals in accordance with API 653 and NCAA airworthiness mandates.

Was this CAC guide helpful to you?

Your feedback helps our legal editorial team keep Nigerian business guides accurate and practical.

Author / Corporate Contributor

CACTalks

Business registration contributor and corporate compliance researcher at CACTalks. Explaining CAC rules, filing procedures, and CAMA 2020 legal requirements in plain, everyday language.

Fact-Checked against CAMA 2020 Provisions & Official CAC Circulars

Leave a Reply

Your email address will not be published. Required fields are marked *

FREE INTERACTIVE RESOURCES

CAC Calculators & Compliance Generators

Simplify your corporate compliance workflow. Use our free, accredited tools built specifically for Nigerian business founders and corporate secretaries.

CALCULATOR

Annual Return Penalty Calculator

Calculate exact late filing default fees and accumulated arrears for Business Names, Limited Companies, and NGOs under CAMA 2020.

Launch Calculator
CHECKER

Name Availability & Eligibility Checker

Screen proposed business names against prohibited keywords, deceptive designations, and restricted corporate categories.

Check Name Rules
GENERATOR

Board Resolution Generator

Instantly draft legally binding ordinary and special resolutions for corporate bank accounts, director appointments, and share allotments.

Generate Document
ACCREDITED FILING ASSISTANCE

Need Hands-on Support with Your CAC Filing or Registration?

Avoid costly portal query rejections, filing delays, or accumulated penalties. Connect directly with our verified corporate compliance specialists for expedited business name registration, company incorporation, and annual return regularizations.

Mon – Fri: 8:00 AM – 6:00 PM WAT Direct WhatsApp & Call Access